{"id":44,"date":"2020-01-13T02:44:13","date_gmt":"2020-01-13T07:44:13","guid":{"rendered":"https:\/\/my.vanderbilt.edu\/seniordesignedema2020\/?p=44"},"modified":"2020-01-13T02:56:53","modified_gmt":"2020-01-13T07:56:53","slug":"update-2","status":"publish","type":"post","link":"https:\/\/my.vanderbilt.edu\/seniordesignedema2020\/2020\/01\/update-2\/","title":{"rendered":"Update #2"},"content":{"rendered":"<p><strong>Order for Spring Prototyping<\/strong><\/p>\n<p>We have successfully research and complied a list of items to be ordered for our project. These will cover the main desired functions of the sleeve: to prevent edema and monitor skin perfusion actively.<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<p><strong>Edema Prevention<\/strong><\/p>\n<p>To actively attempt to prevent edema post operation, we plan to implement mechanically inflatable air bags, much like what is found in a blood pressure cuff. However, these must be slight different, since they will need to provide uniform pressure in three directions and remain in constant balance despite pressure adjustments. Therefore, we have ordered two inflatable cuffs to experiment with orientation and use.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-47\" src=\"https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.27.42-AM-300x293.png\" alt=\"Screen Shot 2020-01-13 at 1.27.42 AM\" width=\"300\" height=\"293\" srcset=\"https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.27.42-AM-300x293.png 300w, https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.27.42-AM-650x634.png 650w, https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.27.42-AM.png 754w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p><strong>Item Link:\u00a0<\/strong><em>https:\/\/www.amazon.com\/Reusable-Ice-Pack-Knee-Compression\/dp\/B072VQPG63\/ref=sr_1_33_sspa?keywords=air+bladders&amp;qid=1577731004&amp;s=hpc&amp;sr=1-33-spons&amp;psc=1&amp;spLa=ZW5jcnlwdGVkUXVhbGlmaWVyPUExWUJZUEJTQU1ZQzEzJmVuY3J5cHRlZElkPUEwMDYxMDczMVNDOVJHUTNPNks0UyZlbmNyeXB0ZWRBZElkPUEwNjc4ODgxMjA1V1A3REtPVk9ETyZ3aWRnZXROYW1lPXNwX2J0ZiZhY3Rpb249Y2xpY2tSZWRpcmVjdCZkb05vdExvZ0NsaWNrPXRydWU=<\/em><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-48\" src=\"https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.28.06-AM-285x300.png\" alt=\"Screen Shot 2020-01-13 at 1.28.06 AM\" width=\"285\" height=\"300\" srcset=\"https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.28.06-AM-285x300.png 285w, https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.28.06-AM-617x650.png 617w, https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.28.06-AM.png 740w\" sizes=\"auto, (max-width: 285px) 100vw, 285px\" \/><\/p>\n<p><strong>Item Link:\u00a0<\/strong><em>https:\/\/www.amazon.com\/Blood-Pressure-Monitor-Upper-Arm\/dp\/B07D6LWQB2\/ref=sr_1_2_sspa?keywords=blood+pressure+cuff+pump&amp;qid=1578436190&amp;s=hpc&amp;sr=1-2-spons&amp;psc=1&amp;spLa=ZW5jcnlwdGVkUXVhbGlmaWVyPUFTMVI2SEpIWlU0TlQmZW5jcnlwdGVkSWQ9QTA5NDM5NjcyOFBVTkZNUU1PUUJIJmVuY3J5cHRlZEFkSWQ9QTA5OTkwNzkyVEdHODZNSVE0WTNBJndpZGdldE5hbWU9c3BfYXRmJmFjdGlvbj1jbGlja1JlZGlyZWN0JmRvTm90TG9nQ2xpY2s9dHJ1ZQ==<\/em><\/p>\n<p>&nbsp;<\/p>\n<p>We plan to measure the local pressure from the cuffs using pressure sensors, which could either act automatically to adjust the pressure, or notify an interface for the patient to create manual adjustments.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-49\" src=\"https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.33.23-AM-300x222.png\" alt=\"Screen Shot 2020-01-13 at 1.33.23 AM\" width=\"300\" height=\"222\" srcset=\"https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.33.23-AM-300x222.png 300w, https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.33.23-AM-768x568.png 768w, https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.33.23-AM-650x481.png 650w, https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.33.23-AM.png 1014w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p><strong>Item Link:<\/strong><em>https:\/\/www.adafruit.com\/product\/1075?gclid=EAIaIQobChMI0_zg7dTZ5gIVxcDACh2jOQ7sEAQYASABEgLpsvD_BwE<\/em><\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<p><strong>Skin Perfusion<\/strong><\/p>\n<p>To measure skin perfusion, we envisioned being able to utilize TcPO2 sensors placed directly on the skin, but those require expensive and elaborate medical equipment. Therefore, we\u00a0will be creating our own leg pulse oximeter, using the circuit located in the more common finger pulse oximeter.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-45 alignnone\" src=\"https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.15.56-AM-300x295.png\" alt=\"Screen Shot 2020-01-13 at 1.15.56 AM\" width=\"267\" height=\"263\" srcset=\"https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.15.56-AM-300x295.png 300w, https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.15.56-AM-768x754.png 768w, https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.15.56-AM-650x639.png 650w, https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.15.56-AM.png 794w\" sizes=\"auto, (max-width: 267px) 100vw, 267px\" \/><\/p>\n<p><strong>Item Link:<\/strong>\u00a0<em>https:\/\/www.amazon.com\/Deluxe-SM-110-Display-Finger-Oximeter\/dp\/B003TJH3LI\/ref=sr_1_1?keywords=transcutaneous+oxygen+sensor&amp;qid=1578418309&amp;sr=8-1<\/em><\/p>\n<p>Finger pulse oximeters measure oxidation by transmitting a red laser through the skin and recording the amount that passes through. This works well on the finger due to its smaller size, but could have issues transmitting through the leg. Therefore, we are also ordering a reflectance sensor, which operates with a very similar mechanism, but with laser reflected back. This method is less impacted by limb volume or size, and can be compared to our transmittance signal.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-46\" src=\"https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.22.46-AM-300x268.png\" alt=\"Screen Shot 2020-01-13 at 1.22.46 AM\" width=\"300\" height=\"268\" srcset=\"https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.22.46-AM-300x268.png 300w, https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.22.46-AM.png 360w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p><strong>Item Link:\u00a0<\/strong><em>https:\/\/www.concordhealthsupply.com\/Nonin-8000r-3ft-Forehead-Infrared-Sensor-p\/non-8000r.htm?gclid=Cj0KCQiA9dDwBRC9ARIsABbedBOYPkOADogMydHR-wkJHR0SxLtqABnaIO6H4bAyCJQgdG4ld2RagpwaAhFcEALw_wcB&amp;click=71<\/em><\/p>\n<p>&nbsp;<\/p>\n<hr \/>\n<p>&nbsp;<\/p>\n<p><strong>Limb Volume<\/strong><\/p>\n<p>To understand the success of this medical device, we are observing limb volume\u00a0to allow for a more well rounded idea of the wound healing process and extent of edema. One way we will potentially be able to do so is with bioimpedance, through sending micro currents through the leg to measure volume.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-50\" src=\"https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.42.45-AM-300x174.png\" alt=\"Screen Shot 2020-01-13 at 1.42.45 AM\" width=\"300\" height=\"174\" srcset=\"https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.42.45-AM-300x175.png 300w, https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.42.45-AM-768x446.png 768w, https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.42.45-AM-650x378.png 650w, https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.42.45-AM.png 988w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p><strong>Item Link:\u00a0<\/strong><em>https:\/\/www.analog.com\/en\/design-center\/evaluation-hardware-and-software\/evaluation-boards-kits\/EVAL-AD5933.html#eb-overview<\/em><\/p>\n<p>&nbsp;<\/p>\n<p>The other effective method is through using soft potentiometers, which could flexibly measure the circumference of the leg, and help assess necessary pressure changes.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-51\" src=\"https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.42.30-AM-300x238.png\" alt=\"Screen Shot 2020-01-13 at 1.42.30 AM\" width=\"300\" height=\"238\" srcset=\"https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.42.30-AM-300x238.png 300w, https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.42.30-AM-768x609.png 768w, https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.42.30-AM-650x515.png 650w, https:\/\/cdn.vanderbilt.edu\/t2-my\/my-prd\/wp-content\/uploads\/sites\/3286\/2020\/01\/Screen-Shot-2020-01-13-at-1.42.30-AM.png 994w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p><strong>Item Link:\u00a0<\/strong><em>https:\/\/www.adafruit.com\/product\/2273<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Order for Spring Prototyping We have successfully research and complied a list of items to be ordered for our project. These will cover the main desired functions of the sleeve: to prevent edema and monitor skin perfusion actively. &nbsp; Edema Prevention To actively attempt to prevent edema post operation, we plan to implement mechanically inflatable&#8230;<\/p>\n","protected":false},"author":8568,"featured_media":53,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-44","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"_links":{"self":[{"href":"https:\/\/my.vanderbilt.edu\/seniordesignedema2020\/wp-json\/wp\/v2\/posts\/44","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/my.vanderbilt.edu\/seniordesignedema2020\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/my.vanderbilt.edu\/seniordesignedema2020\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/my.vanderbilt.edu\/seniordesignedema2020\/wp-json\/wp\/v2\/users\/8568"}],"replies":[{"embeddable":true,"href":"https:\/\/my.vanderbilt.edu\/seniordesignedema2020\/wp-json\/wp\/v2\/comments?post=44"}],"version-history":[{"count":2,"href":"https:\/\/my.vanderbilt.edu\/seniordesignedema2020\/wp-json\/wp\/v2\/posts\/44\/revisions"}],"predecessor-version":[{"id":55,"href":"https:\/\/my.vanderbilt.edu\/seniordesignedema2020\/wp-json\/wp\/v2\/posts\/44\/revisions\/55"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/my.vanderbilt.edu\/seniordesignedema2020\/wp-json\/wp\/v2\/media\/53"}],"wp:attachment":[{"href":"https:\/\/my.vanderbilt.edu\/seniordesignedema2020\/wp-json\/wp\/v2\/media?parent=44"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/my.vanderbilt.edu\/seniordesignedema2020\/wp-json\/wp\/v2\/categories?post=44"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/my.vanderbilt.edu\/seniordesignedema2020\/wp-json\/wp\/v2\/tags?post=44"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}